Indian J Ophthalmol ; 2020 Jan; 68(1): 226-229
Article | IMSEAR | ID: sea-197773

ABSTRACT

We report the use of two corneal grafts derived from a donor, with a history of early stage keratoconus, for lamellar and penetrating keratoplasty. The first graft was used to perform Descemet stripping automated endothelial keratoplasty (DSAEK) in a patient with endothelial dysfunction and advanced pseudoexfoliative glaucoma. The second graft was used for an emergency penetrating keratoplasty in a patient with corneal perforation secondary to uncontrolled herpes keratitis. In the first case, 1 year postoperatively, the graft was clear and attached with no signs of rejection or failure. In the second case, the perforation did not relapse after keratoplasty and the globe retained its structural integrity during the 1-year follow-up.

2.
Indian J Ophthalmol ; 2020 Jan; 68(1): 174-176
Article | IMSEAR | ID: sea-197738

ABSTRACT

We describe an effective technique for the management of graft杊ost interface haze associated with interface deposits after Descemet-stripping automated endothelial keratoplasty (DSAEK) with bimanual irrigation/aspiration. A Tan marginal dissector was used to separate the graft from the stroma in the nasal two-thirds of the graft杊ost interface. The aspiration handpiece was inserted in the interface through the nasal side-port corneal incision and a separate irrigation tip was placed in the anterior chamber (AC) through the temporal corneal paracentesis. Meticulous rinsing of the two-thirds of the interface area and the AC was performed. At the end of the procedure, air was injected into the AC to float the donor graft against the host stromal bed and facilitate graft adherence. Postoperative anterior segment optical coherence tomography and slit-lamp examination confirmed elimination of the interface haze杁eposits and a well-attached graft. An improvement in visual acuity was noted.

3.
Indian J Ophthalmol ; 2019 Jan; 67(1): 8-15
Article | IMSEAR | ID: sea-197079

ABSTRACT

Corneal cross-linking (CXL), introduced by Wollensak et al. in 2003, is a minimally invasive procedure to halt the progression of keratoconus. Conventional CXL is recommended in eyes with corneal thickness of at least 400 microns after de-epithelialization to prevent endothelial toxicity. However, most of the keratoconic corneas requiring CXL may not fulfill this preoperative inclusion criterion. Moderate-to-advanced cases are often found to have a pachymetry less than this threshold. There are various modifications to the conventional method to circumvent this issue of CXL thin corneas while avoiding the possible complications. This review is an update on the modifications of conventional CXL for thin corneas.